Top Page Our Products Top > WA-Type: For waste gas containing high temperature and high density dust
Our Products

WA-Type: High temperature and with large dust content

PDF

FEATURES OF PRODUCTS

・BI-DRUM TYPE NATURAL CIRCURATION BOILER
Boiler design is Bi-drum and natural circulation type. It is excellent at gas tight because of membrane structure.
・HIGHT TEMPERATURE GAS AND WITH LARGE DUST CONTENT
Applicable for such higher temperature waste gas as from the municipal waste incinerator, which have large gas volume, large dust content.
・PREVENTION OF DUCT ADHESION
Possible to run continuously for a long time. Even if the clinkers stick to water screen, it can remove the clinker naturally, and that, the boiler performance may not decline.
・ARRANGEMENT
Possible to install at both top and back of the incinerator.
・EASY DUST REMOVAL
Draft loss is small, and convection part can remove the dust by steam type soot blower easily.

SPECIFICATION

●APPLICATION●
For the municipal waste incinerator, or the waste gas with large dust content

●APPLICABLE RANGE●
Gas temperature at inlet      Less than 1200oC
Nature of dust      Larger dust content with tenacity
Incineration volume for municipal waste      More than 120 ton/24 hour

CONSTRUCTION

Inquiries about Products